Home » Products » Relay & Contactor » Relay » Protection Relay » REL52008 Schneider Electric Easergy P3U30, 4L ringlug, 4U, 16DI/8DO, Uaux: 48-230V, DI:110-230V, 2 x RJ-45

REL52008 Schneider Electric Easergy P3U30, 4L ringlug, 4U, 16DI/8DO, Uaux: 48-230V, DI:110-230V, 2 x RJ-45

240,000.00 EGP

REL52008 Schneider Electric
Protection Relay

Quantity Price Discount
10-20 235,200.00 EGP 2%
21-100 228,000.00 EGP 5%
101-200 222,000.00 EGP 7.5%
201+ 216,000.00 EGP 10%

Available on backorder

SKU: REL52008 Category: Tags: ,
Description

REL52008 Schneider Electric Easergy P3U30, 4L ringlug, 4U, 16DI/8DO, Uaux: 48-230V, DI:110-230V, 2 x RJ-45

Perfectly suited for buildings and industry, utilities, and large industrial processes. The relay include protection for overcurrent, overload, broken conductor, earth-fault and breaker failure as per ANSI. It also feature an automatic recloser, a switch ON to fault, inrush protection and lockout among others. Simple, reliable, safe and easy-to-use, thanks to the User Interface display. The protection relay can to be supplied by a 48 VAC/VDC to 230 VAC/VDC network. It include 16 digital inputs, 2 RJ45 communication port and 1 USB on front of the device. Mechanical dimensions are 169.5 mm in height, 170 mm in width and 205 mm in depth. The relays are certified with EN 60255-26 for electromagnetic compatiblity. The device is compatible with aditional modules and accessories: connection cables, communication modules, temperature and analogue input and output modules, LPVT & PLCT option, arc flash sensors, and other accessories.

Datasheet:

Download REL52008

Specifications
Shipping Weight3 kg
BrandSchneider Electric
SeriesPowerLogic P3
ModelREL52008
Supply48…230 V AC/DC
measuring inputs: 1/5 A CT phase current 3 : 1/5 A CT residual current 1 : 100 V/110 V VT voltage 4
protection functionsPhase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Directional earth fault 67N Transient earth fault 67NI Capacitor bank unbalance 51C Broken conductor 46 I2/I1 Cold load pick-up Switch ON to fault (SOTF) Breaker failure 50BF Directional active underpower 37P Fault locator 21FL Recloser 79 Phase undercurrent 37 Excessive starting time, locked rotor 48/51LR Motor restart inhibition 66 Capacitor overvoltage 59C Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Positive sequence undervoltage 27P Earth fault overvoltage 59N Underfrequency 81/81N Rate of change of frequency 81R Synchro-check 25 Lockout relay 86 CT supervision 60 VT supervision 60 H2 detection 68H2 H5 detection 68H5 Negative sequence overcurrent 47 Programmable stages 99 Programmable curve
Datasheet